Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Oral Health ; 24(1): 134, 2024 Jan 26.
Article in English | MEDLINE | ID: mdl-38279099

ABSTRACT

The aim of the present study was to analyze and compare the angle deviation of two, four and six adjacent dental implants placed with and without straight parallel pins. MATERIALS AND METHODS: Two hundred and forty (240) dental implants were selected and randomly allocated into the following study groups: Two dental implants placed with straight parallel pins (Ref.: 144-100, BioHorizons, Birmingham, AL, USA) (n = 10) (2PP); Two dental implants placed without parallel pins (n = 10) (2withoutPP); Four dental implants placed with straight parallel pins hT(n = 10) (4PP); Four dental implants placed without parallel pins (n = 10) (4withoutPP); Six dental implants placed with straight parallel pins (n = 10) (6PP) and Six dental implants placed without parallel pins (n = 10) (6withoutPP). The dental implants randomly assigned to groups 2PP and 2withoutPP were placed into standardized polyurethane models of partially edentulous upper jaws in tooth positions 2.4 and 2.6, the dental implants randomly assigned to groups 4PP and 4withoutPP were placed into standardized polyurethane models of fully edentulous upper jaws in tooth positions 1.6, 1.4, 2.4 and 2.6, and the dental implants randomly assigned to groups 6PP and 6withoutPP were placed into standardized polyurethane models of fully edentulous upper jaws in tooth positions 1.6, 1.4, 1.2, 2.2, 2.4 and 2.6. Afterwards, postoperative CBCT scans and digital impressions were aligned in a 3D implant-planning software to compare the angle deviation (°) of two, four and six adjacent dental implants placed with and without straight parallel pins using the General Linear Model statistical analysis. RESULTS: Statistically significant differences were found between the angle deviation of 2 dental implants placed with straight parallel pins (p < 0.0001) and between the angle deviation of 4 dental implants placed with straight parallel pins (p = 0.0024); however, no statistically significant differences were found in the angle deviation of 6 dental implants placed with straight parallel pins (p = 0.9967). CONCLUSION: The use of a straight parallelization pin results in lower angle deviation between two and four adjacent dental implants; however, it is not effective for a larger number of dental implants.


Subject(s)
Dental Implants , Jaw, Edentulous , Surgery, Computer-Assisted , Humans , Dental Implantation, Endosseous/methods , Polyurethanes , Surgery, Computer-Assisted/methods , Imaging, Three-Dimensional , Computer-Aided Design , Cone-Beam Computed Tomography
2.
BMC Oral Health ; 23(1): 542, 2023 08 05.
Article in English | MEDLINE | ID: mdl-37543581

ABSTRACT

To analyze and compare the accuracy and root contact prevalence, comparing a conventional freehand technique and two navigation techniques based on augmented reality technology for the orthodontic self-drilling mini-implants placement. Methods Two hundred and seven orthodontic self-drilling mini-implants were placed using either a conventional freehand technique (FHT) and two navigation techniques based on augmented reality technology (AR TOOTH and AR SCREWS). Accuracy across different dental sectors was also analyzed. CBCT and intraoral scans were taken both prior to and following orthodontic self-drilling mini-implants placement. The deviation angle and horizontal were then analyzed; these measurements were taken at the coronal entry point and apical endpoint between the planned and performed orthodontic self-drilling mini-implants. In addition, any complications resulting from mini-implant placement, such as spot perforations, were also analyzed across all dental sectors.Results The statistical analysis showed significant differences between study groups with regard to the coronal entry-point (p < 0.001), apical end-point(p < 0.001) and angular deviations (p < 0.001). Furthermore, statistically significant differences were shown between the orthodontic self-drilling mini-implants placement site at the coronal entry-point (p < 0.0001) and apical end-point (p < 0.001). Additionally, eight root perforations were observed in the FHT group, while there were no root perforations in the two navigation techniques based on augmented reality technology.Conclusions The navigation techniques based on augmented reality technology has an effect on the accuracy of orthodontic self-drilling mini-implants placement and results in fewer intraoperative complications, comparing to the conventional free-hand technique. The AR TOOTH augmented reality technique showed more accurate results between planned and placed orthodontic self-drilling mini-implants, comparing to the AR SCREWS and conventional free-hand techniques. The navigation techniques based on augmented reality technology showed fewer intraoperative complications, comparing to the conventional free-hand technique.


Subject(s)
Augmented Reality , Dental Implants , Orthodontic Anchorage Procedures , Humans , Technology , Intraoperative Complications
3.
BMC Oral Health ; 23(1): 86, 2023 02 11.
Article in English | MEDLINE | ID: mdl-36774459

ABSTRACT

The objective of the present study was to evaluate and compare the effect of the computer-aided static navigation technique on the accuracy of the maxillary skeletal expansion (MSE) appliances. MATERIAL AND METHODS: Forty orthodontic self-drilling mini-implants were placed in ten anatomically based standardized polyurethane models of a completely edentulous upper maxilla, manufactured using a 3D impression procedure. The four orthodontic self-drilling mini-implants for anchoring the MSE appliance were digitally planned on 3D planning software, based on preoperative cone-beam computed tomography (CBCT) scan and a 3D extraoral surface scan. Afterwards, the surgical templates were virtually planned and manufactured using stereolithography. Subsequently, the orthodontic self-drilling mini-implants were placed an postoperative CBCT scans were performed. Finally, coronal entry-point, apical end-point and angular deviations were calculated using a t-test for independent samples or a non-parametric Signed Rank test. RESULTS: Statistically significant differences were not shown at coronal entry-point (p = 0.13), apical end-point (p = 0.41) and angular deviations (p = 0.27) between the planned and performed orthodontic self-drilling mini-implants. CONCLUSIONS: Computer-aided static navigation technique enables accurate orthodontic mini-implant placement for the MSE appliances.


Subject(s)
Dental Implants , Orthodontic Anchorage Procedures , Surgery, Computer-Assisted , Humans , Surgery, Computer-Assisted/methods , Dental Implantation, Endosseous/methods , Computers , Cone-Beam Computed Tomography/methods , Computer-Aided Design , Imaging, Three-Dimensional
4.
J Pers Med ; 11(11)2021 Oct 26.
Article in English | MEDLINE | ID: mdl-34834446

ABSTRACT

In the present retrospective study, we aimed to assess the replicability and reproducibility of a novel digital measurement technique for analyzing the volumes of the left and right maxillary sinuses and the nasal and maxillary sinus airway complex after a sinus lift procedure using the lateral window approach, to provide an accurate measurement technique for easily applying in clinical practice and to allow pre-operative assessment of maxillary sinus lift surgery, avoiding complications and making surgery more predictable. MATERIAL AND METHODS: Thirty patients with partially edentulous posterior maxilla were selected and submitted to bilateral sinus lift using the lateral window approach technique, with grafting materials selected and submitted to cone beam computed tomography (CBCT) scans, both pre- and postoperatively. Then, datasets were uploaded to therapeutic digital planning software to measure the volume of the right and left maxillary sinuses and the nasal and maxillary sinus airway complex. Gage R&R statistical analysis was performed to assess the replicability and reproducibility of the digital measurement technique. RESULTS: The variability attributable to the novel digital measurement technique was 3.4% for replicability and 3.4% for reproducibility of the total variability of the samples. CONCLUSION: The novel digital method proposed is a replicable and reproducible technique for analyzing the volume of the right and left maxillary sinuses and the nasal and maxillary sinus airway complex after a sinus lift using the lateral window approach technique, allowing an accurate pre-operative assessment of maxillary sinus lift surgery, avoiding complications and making surgery more predictable.

5.
Biology (Basel) ; 10(7)2021 Jun 29.
Article in English | MEDLINE | ID: mdl-34209770

ABSTRACT

The aim of this systematic review and meta-analysis was to analyze and compare the survival rate and prosthetic and sinus complications of zygomatic dental implants for the rehabilitation of the atrophic edentulous maxilla. MATERIALS AND METHODS: We conducted a systematic literature review and meta-analysis, based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) recommendations, of clinical studies that evaluated the survival rate and prosthetic and sinus complications of zygomatic dental implants for the rehabilitation of the atrophic edentulous maxilla. Four databases were consulted during the literature search: Pubmed-Medline, Scopus, Embase, and Web of Science. After eliminating duplicate articles and applying the inclusion criteria, 46 articles were selected for the qualitative analysis and 32 for the quantitative analysis. RESULTS: Four randomized controlled trials, 19 prospective clinical studies, 20 retrospective studies, and 3 case series were included in the meta-analysis. Conventional dental implants failure (n = 3549) were seen in 2.89% (IC-95% 1.83-3.96%), while zygomatic dental implants failure (n = 1895) were seen in 0.69% (IC-95% 0.21-1.16%). The measure of the effect size used was the Odds Ratio, which was estimated at 2.05 with a confidence interval of 95% between 1.22 and 3.44 (z test = 2.73; p-value = 0.006). The failure risk of conventional dental implants is 2.1 times higher than that of zygomatic dental implants. Slight heterogeneity was determined in the meta-analysis between 23 combined studies (Q test = 32.4; p-value = 0.070; I2 = 32.1%). Prosthetic complications were recorded in 4.9% (IC-95% 2.7-7.3%) and mild heterogeneity was observed in a meta-analysis of 28 combined studies (Q test = 88.2; p-value = 0.001; I2 = 69.4%). Sinus complications were seen in 4.7% (IC-95% 2.8-6.5%) and mild heterogeneity was observed in a meta-analysis of 32 combined studies (Q test = 75.3; p-value = 0.001; I2 = 58.8%). CONCLUSIONS: The high survival rate and low prosthetic and sinus complications related to zygomatic dental implants suggest the use of zygomatic dental implants for the rehabilitation of the atrophic edentulous maxilla.

SELECTION OF CITATIONS
SEARCH DETAIL
...